Free 30-minute AI & automation audit with a senior engineer. You keep the notes. Book yours

HL7 v2 Interfaces

HL7 Interface Engine Development, Channel Migration and Support

An HL7 interface engine is the middleware that receives, validates, transforms and routes HL7 v2 messages, such as ADT admissions, ORM and OML orders and ORU results, between hospital systems over MLLP or files. MultiGenesys builds and supports interface engine channels, migrates channels between engines, and builds lightweight custom HL7 services where a full engine is more than you need, with monitoring, alerting and message replay so no admission or result is lost silently.

Clinician reviewing patient health data on a tablet in a clinic

Outcomes

What you get

No silent message loss

Every message is acknowledged, logged and either delivered or parked in an error queue that someone is alerted to, with one-click replay after a fix.

Interfaces your team can read

Each channel has a mapping specification, sample messages and tests, so the next engineer does not have to reverse-engineer a script.

Engine choice on your terms

Channels are documented and portable, so licensing or vendor changes do not lock you in.

Faster partner onboarding

Reusable channel templates for common feeds make a new lab, clinic or imaging partner a configuration task rather than a project.

What’s included

HL7 Interface Engine Development, end to end

ADT feeds

Admit, transfer, discharge, register, update and merge events (A01, A02, A03, A04, A08, A40 and others) with PID, PV1, NK1 and IN1 mapping to downstream systems.

Orders and results

ORM^O01 and OML^O21 orders with ORC and OBR segments, and ORU^R01 results with OBX observations, including embedded PDF reports and microbiology results.

Scheduling, documents and charges

SIU scheduling messages, MDM document notifications, DFT charge posting and VXU immunization updates where your workflow needs them.

MLLP and transport

MLLP listeners and senders with correct framing, TLS or VPN tunnels, file and SFTP drops, and HTTP or queue bridges to cloud services.

Validation and acknowledgments

Message validation against the agreed HL7 version and site profile, MSA acknowledgment codes (AA, AE, AR) and enhanced acknowledgment where partners support it.

Engine channel migration

Inventory, documentation and migration of channels between engines or onto custom services, with side-by-side message comparison before cutover.

HL7 v2 to FHIR bridging

Channels that convert v2 events into FHIR R4 resources for apps and exchanges, while the hospital keeps its v2 feeds.

Monitoring and on-call

Dashboards for queue depth, throughput, error rates and partner connectivity, alerts on stalled channels and a runbook for every failure type.

Process

How an HL7 Interface Engine Development engagement runs

Clear stages, working software at every step, and the same team from first workshop to production support.

  1. 01

    Step 1

    Interface inventory

    We list every channel, partner, message type, version, transport and owner, and capture sample traffic for each.

  2. 02

    Step 2

    Specification

    We write or recover the mapping specification for each interface, including Z-segments and local code tables.

  3. 03

    Step 3

    Build and test

    We build channels with automated tests that replay captured messages and compare outputs field by field.

  4. 04

    Step 4

    Parallel run

    For migrations, old and new channels process the same traffic, and differences are reviewed before the switch.

  5. 05

    Step 5

    Support

    We monitor channels, handle partner upgrades and certificate renewals, and add new feeds from templates.

Why MultiGenesys for HL7 Interface Engine Development

HL7 v2 is old, terse and everywhere. Most hospital traffic still runs on it: every admission, transfer, lab result and radiology report. The standard is flexible enough that two systems both claiming v2.5.1 can disagree on where the attending doctor or the result status lives. Good interface work is therefore mostly specification and testing, and only partly code. We capture real traffic, write the mapping down and test every channel by replaying that traffic.

Healthcare platforms we have worked on

We have worked on EMR, hospital management, patient engagement, scheduling and provider-data platforms, including in the US. Relevant to interface work: a US patient engagement and self-scheduling platform connected to many EHRs, an open-source EMR platform used by hospitals and clinics in low-resource settings, a hospital management system vendor and a US provider-data management platform. The work covered integration and interoperability, feature development and data work. One example is public: our patient scheduling and EHR integration use case.

When the engine itself becomes the risk

Interface engines accumulate years of channels written by people who have moved on. When licensing changes, as with Mirth Connect’s move to commercial-only licensing in 2025, or when the engine server needs an upgrade, teams discover they cannot say what each channel does. We start by documenting every channel from its configuration and live traffic, then decide with you whether to upgrade, license, or migrate. Migration runs side by side, and outputs are compared message by message.

Part of a wider interoperability practice

This page focuses on HL7 v2 channels and engines. For the overall interoperability architecture, including FHIR APIs and SMART on FHIR apps, see HL7 integration and FHIR development. For lab analyzer and imaging feeds, see LIS, RIS and PACS integration. For the hospital systems that produce ADT events, see hospital management system development. Our system integration practice applies the same monitoring and replay discipline outside healthcare. Background reading: HL7 v2 vs FHIR.

Technologies we use

  • HL7 v2.3 to v2.8
  • MLLP / TLS
  • Mirth Connect
  • HAPI HL7v2
  • Apache Camel
  • Java / Spring Boot
  • Node.js / TypeScript
  • Apache Kafka / RabbitMQ
  • Azure Health Data Services / Google Cloud Healthcare API
  • PostgreSQL
  • Prometheus / Grafana / Loki

Engagement models

Work with us the way that suits you

How we work

Dedicated product team

A stable, cross-functional team — engineers, design, QA, DevOps — that owns your roadmap quarter after quarter.

Fixed-scope delivery

A defined build with milestones, demos and a hard definition of done.

Embedded engineers

Senior engineers inside your team, in your tools and your stand-ups, with no hand-over boundary.

Working standards

What you can expect on every project

Engineering standards

Reviewed, version-controlled code

Every change goes through pull requests and peer review in your repository, with a clean history you own.

Automated testing in CI/CD

Unit, integration and API tests run in the pipeline on every change, so regressions are caught before release.

Security by default

Least-privilege access, secrets management, OWASP-aligned checks and environment separation from day one.

Production-ready by default

Idempotent APIs, audit trails, monitoring, alerting, backups and documented runbooks ship with every platform.

Frequently asked questions

Still unsure? Ask us directly — we reply within one business day.

Mirth Connect is no longer open source. What are our options?

NextGen moved Mirth Connect to a commercial-only license from version 4.6, announced in March 2025, and named 4.5.2 as the last open-source release. Your options are to license the commercial edition, stay on 4.5.2 and accept no further updates, or move channels to another engine or custom services. We help you document channels and compare the cost and risk of each path.

Do we need an interface engine at all?

Not always. A product with two or three stable feeds can run them as small, well-tested services. Hospitals and integration hubs with dozens of partners usually benefit from an engine's routing, monitoring and replay.

Which HL7 v2 version do you support?

All versions in common use, from 2.3 through 2.5.1 and later. In practice each partner has its own variant, so we build to the partner's specification and sample messages rather than the version number alone.

How do you secure HL7 traffic?

MLLP has no built-in encryption, so we run it inside TLS or a site-to-site VPN, restrict listeners by network and certificate, and avoid logging full message content in plain text outside protected stores.

Can you convert our HL7 v2 feeds to FHIR?

Yes. We add conversion channels that turn ADT, ORU and other events into FHIR R4 resources, and for full moves see our FHIR migration service.

Can you support interfaces outside business hours?

Yes. We agree the support window and response times in the engagement, combining alerting with on-call engineers in Pune, which gives working-hours overlap with Australia, Singapore, the Gulf and Europe.

Tell us what you’re building. We’ll show you how we’d ship it.

Share a few lines about your project. A senior engineer — not a salesperson — replies within one business day.

Free AI audit Book a call