Free 30-minute AI & automation audit with a senior engineer. You keep the notes. Book yours

Lab & Imaging Integration

LIS, RIS and PACS Integration for Laboratories and Imaging Departments

LIS, RIS and PACS integration connects laboratory information systems, radiology information systems and picture archiving systems with analyzers, imaging modalities, hospital systems and EHRs, so orders flow out and results, reports and images flow back without re-keying. MultiGenesys builds analyzer interfaces, HL7 v2 order and result feeds, DICOM modality worklist and DICOMweb integrations, and FHIR APIs for lab and imaging data, with the audit trails regulated laboratories expect.

Clinician reviewing patient health data on a tablet in a clinic

Outcomes

What you get

No transcription errors

Orders reach analyzers and modalities with the right patient and test, and results return to the record without anyone retyping a value.

Faster turnaround

Results and reports are released to clinicians and patients as soon as they are verified, instead of waiting for a batch upload or courier.

Images where clinicians work

Radiology reports and image links appear in the EHR and referring portals, with a viewer that opens the right study.

Traceability from sample to report

Each result carries who ordered it, which instrument produced it, who verified it and when it was released.

What’s included

LIS, RIS and PACS Integration, end to end

Lab analyzer interfaces

Bidirectional and unidirectional interfaces with analyzers over ASTM (CLSI LIS2-A2) and HL7, using serial, TCP and file transports, including middleware for host query.

Orders and results with HL7 v2

ORM^O01 or OML^O21 orders with ORC and OBR segments and ORU^R01 results with OBX observations between HMIS, EHR, LIS and RIS, plus cancellations and corrected results.

DICOM modality worklist

Modality worklist (MWL) so scanners pick the scheduled patient and procedure, and MPPS status updates back to the RIS.

PACS and DICOMweb

Storage, query and retrieval through DICOM C-STORE and C-FIND or DICOMweb QIDO-RS, WADO-RS and STOW-RS, and zero-footprint viewer launch from the EHR.

FHIR for lab and imaging

ServiceRequest, Specimen, Observation, DiagnosticReport and ImagingStudy resources for apps, portals and exchanges, with LOINC codes on lab results.

Lab portals and reporting

Client and patient portals for ordering, tracking and downloading signed reports, with multi-signature approval for certified results.

Reference lab and exchange feeds

Feeds from hospital labs to reference labs and from labs to national or regional exchanges, such as My Health Record in Australia or Malaffi in Abu Dhabi.

Image de-identification

Removal of patient identifiers from DICOM headers and burned-in text before images reach research or AI pipelines.

Process

How an LIS, RIS and PACS Integration engagement runs

Clear stages, working software at every step, and the same team from first workshop to production support.

  1. 01

    Step 1

    Department survey

    We list every analyzer, modality, system, interface protocol and code table, and capture sample messages and DICOM headers.

  2. 02

    Step 2

    Test code mapping

    We map local test codes to LOINC and procedure codes to your catalog, and agree units, reference ranges and result statuses.

  3. 03

    Step 3

    Build and simulate

    We build interfaces and test them with simulators and recorded traffic before touching live instruments.

  4. 04

    Step 4

    Validate on site

    We run parallel testing with real samples or phantom studies, compare outputs and get department sign-off.

  5. 05

    Step 5

    Support

    We monitor interfaces, handle instrument replacements and new tests, and keep mappings current.

Why MultiGenesys for LIS, RIS and PACS Integration

Laboratories and imaging departments are where clinical data is produced in volume and where a mismatched identifier does the most harm. We treat every interface as a patient-safety control: positive patient identification on every order, explicit handling of cancellations and corrections, and a reconciliation report that shows any order without a result.

From our laboratory work

Our laboratory platform work, described on our healthcare industry page, covers commercial testing laboratories end to end: sample registration and chain of custody, testing against methods and specifications, multi-signature result approval, certified PDF reports and white-labeled client portals, with audit history on nearly every entity. That discipline of traceability carries into clinical lab and imaging integration.

Standards that matter here

Lab integration still runs largely on ASTM and HL7 v2. Imaging runs on DICOM, with DICOMweb now the practical choice for web viewers and cloud archives. FHIR is increasingly the interface outward, to apps, patient portals and national records: DiagnosticReport and Observation for lab results, ImagingStudy for studies. Australia’s Share by Default rules, in force since July 2026, make pathology and diagnostic imaging report upload to My Health Record a condition for some Medicare benefits. In the Gulf, Abu Dhabi’s Malaffi and Dubai’s NABIDH expect lab results from reporting facilities. We build each of these feeds from the same verified results.

For the HL7 channel layer, see HL7 interface engine development. For hospital-wide operations, see hospital management system development. For AI on reports and images, see healthcare AI and clinical document processing and computer vision and OCR. For the broader interoperability architecture, see HL7 and FHIR integration. Book a 30-min call to review your instruments and systems.

Technologies we use

  • ASTM / CLSI LIS2-A2
  • HL7 v2.x / MLLP
  • DICOM / DICOMweb
  • HL7 FHIR R4 / HAPI FHIR
  • LOINC / UCUM
  • dcm4che / Orthanc
  • OHIF Viewer
  • Java / Spring Boot
  • Node.js / TypeScript
  • PostgreSQL
  • Angular
  • AWS S3 / Azure Blob Storage

Engagement models

Work with us the way that suits you

How we work

Dedicated product team

A stable, cross-functional team — engineers, design, QA, DevOps — that owns your roadmap quarter after quarter.

Fixed-scope delivery

A defined build with milestones, demos and a hard definition of done.

Embedded engineers

Senior engineers inside your team, in your tools and your stand-ups, with no hand-over boundary.

Working standards

What you can expect on every project

Engineering standards

Reviewed, version-controlled code

Every change goes through pull requests and peer review in your repository, with a clean history you own.

Automated testing in CI/CD

Unit, integration and API tests run in the pipeline on every change, so regressions are caught before release.

Security by default

Least-privilege access, secrets management, OWASP-aligned checks and environment separation from day one.

Production-ready by default

Idempotent APIs, audit trails, monitoring, alerting, backups and documented runbooks ship with every platform.

Frequently asked questions

Still unsure? Ask us directly — we reply within one business day.

Can you interface our lab analyzers?

Yes, for analyzers that expose ASTM or HL7 interfaces over serial, TCP or files, which covers most modern instruments. We use the manufacturer's interface specification and test with a simulator before connecting live.

What is the difference between a LIS, a RIS and a PACS?

A LIS manages laboratory orders, samples and results. A RIS manages radiology scheduling, workflow and reports. A PACS stores and serves medical images in DICOM format. Hospitals usually need all three connected to each other and to the EHR.

Can radiology images be viewed in our EHR?

Yes. The usual pattern is a report sent to the EHR over HL7 v2 or FHIR with a link that opens the study in a zero-footprint web viewer using DICOMweb, so images stay in the PACS.

Have you built laboratory software before?

Yes. Our laboratory platform work covers sample registration, chain of custody, test plans, QC queues, multi-signature result approval and certified PDF reports, as described on our healthcare industry page.

How do you handle corrected or amended results?

Corrections are sent as new messages with a corrected result status, and the downstream record keeps the history. We test correction and cancellation flows as carefully as normal results.

Do you meet Australia's Share by Default rules for pathology and imaging?

We build the upload interfaces and workflow. Since 1 July 2026, Australian pathology and diagnostic imaging providers have been required to upload most reports to My Health Record under the Share by Default rules, and the provider remains responsible for meeting them.

Tell us what you’re building. We’ll show you how we’d ship it.

Share a few lines about your project. A senior engineer — not a salesperson — replies within one business day.

Free AI audit Book a call