Free 30-minute AI & automation audit with a senior engineer. You keep the notes. Book yours

Internet of Medical Things

IoMT Development: Connected Medical Devices and Remote Patient Monitoring

IoMT (Internet of Medical Things) development is the engineering of connected health devices and the software around them: device connectivity over Bluetooth Low Energy, Wi-Fi or cellular, gateways and mobile apps that collect readings, cloud pipelines that validate and store them, and clinical integration that delivers them into the EHR as FHIR Observation resources. MultiGenesys builds remote patient monitoring platforms and device data pipelines with security designed in, and works within the medical-device rules, such as IEC 62304 and EU MDR, that apply to your product.

Clinician reviewing patient health data on a tablet in a clinic

Outcomes

What you get

Readings that reach the care team

Blood pressure, glucose, SpO2, weight and ECG readings arrive in the clinician's workflow as coded observations, not as screenshots or phone calls.

Alerts that are worth reading

Per-patient thresholds, trend rules and escalation paths flag the readings that need action and suppress the noise that causes alert fatigue.

Devices you can trust in the field

Provisioning, certificate-based identity, signed firmware updates and fleet monitoring keep each device known, current and accounted for.

Evidence for regulators and buyers

Architecture, risk and cybersecurity documentation produced as you build, ready for your quality system and hospital security reviews.

What’s included

IoMT Development, end to end

Device connectivity

Bluetooth Low Energy health profiles such as Blood Pressure, Glucose, Heart Rate and Pulse Oximeter, vendor SDKs and cloud APIs, Wi-Fi and cellular devices, and gateways on Raspberry Pi or ESP32 hardware.

Patient and caregiver apps

Flutter or React Native apps that pair devices, collect readings offline, remind patients to measure and show trends in plain language.

Device data pipelines

MQTT ingestion through AWS IoT Core, Azure IoT Hub or Mosquitto, validation, unit normalization, de-duplication and time-series storage in InfluxDB or PostgreSQL.

FHIR Observation delivery

Readings mapped to FHIR R4 Observation with LOINC codes and the vital-signs profiles, such as 85354-9 for a blood pressure panel and 59408-5 for SpO2, linked to Device and Patient resources.

Clinician dashboards and alerting

Monitoring dashboards, worklists of patients outside range, escalation to nurses or doctors, and time logs for monitoring programs that need them.

Edge processing

Filtering, buffering and simple rules on the gateway, so the system keeps working through poor connectivity and sends only what the cloud needs.

Security engineering

Per-device X.509 certificates, mutual TLS, encrypted storage, signed over-the-air updates, a software bill of materials and threat modeling aligned to IEC 81001-5-1.

Regulatory support for your team

Software lifecycle documentation, traceability from requirements to tests and risk inputs that your quality team uses for IEC 62304, ISO 14971, FDA or EU MDR submissions.

Process

How an IoMT Development engagement runs

Clear stages, working software at every step, and the same team from first workshop to production support.

  1. 01

    Step 1

    Clinical use and classification

    We start with the clinical use, the devices and who acts on the data, and confirm with your regulatory lead whether the software is a medical device and its class.

  2. 02

    Step 2

    Architecture and risk

    We design device, edge, cloud and EHR integration together, with a threat model and hazard inputs recorded from the start.

  3. 03

    Step 3

    Prototype with real devices

    We connect actual devices early to learn their quirks, such as clock drift, duplicate readings and pairing failures.

  4. 04

    Step 4

    Build and verify

    We build in increments with automated tests, traceability and documentation suitable for your quality system.

  5. 05

    Step 5

    Pilot and scale

    We pilot with a small patient group, tune alerts with clinicians and then scale devices, patients and integrations.

Why MultiGenesys for IoMT Development

Remote patient monitoring breaks at the edges. A blood pressure cuff reports in a time zone it was never set to. A patient pairs two devices and readings arrive twice. A gateway loses power for a weekend and floods the server on Monday. These problems are not visible in a demo, so we connect real devices in the first weeks and design the pipeline around what they actually do.

Built on our IoT practice

Our IoT development practice builds the full chain: firmware integration on ESP32, Arduino and Raspberry Pi, MQTT messaging, AWS IoT Core or Azure IoT Hub, InfluxDB and Grafana. Our embedded and firmware development team works at the device level. Our care technology work includes IoT-based health monitoring for elderly care, described on our healthcare industry page. IoMT adds three things on top of general IoT: clinical coding of every reading, integration into clinical systems, and medical-device regulatory discipline.

Regulatory awareness, not regulatory claims

We are a software engineering partner, not a device manufacturer, and we hold no medical-device certifications. What we bring is engineering that fits a regulated process: requirements traced to tests, software of unknown provenance (SOUP) listed and versioned, risk inputs for ISO 14971, a software bill of materials, and a secure update path. Under the EU MDR, much clinical decision software falls into class IIa or higher under Rule 11, so planning for documentation early saves rework later.

Regional context

National programs increasingly expect monitoring data to flow into shared records. In Australia, My Health Record is the national summary, and in Singapore the National Electronic Health Record (NEHR). In the EU, the European Health Data Space sets common rules for electronic health record systems and wellness applications that claim interoperability. In India, ABDM links records to a patient’s ABHA. We map device data so it can follow those paths. For data analysis on top of monitoring, see healthcare AI and clinical document processing and predictive analytics. For virtual visits alongside monitoring, see telehealth platform development. Book a 30-min call to discuss your devices and clinical use.

Technologies we use

  • Bluetooth Low Energy
  • MQTT / Mosquitto
  • AWS IoT Core / Azure IoT Hub
  • ESP32 / Raspberry Pi
  • Node-RED
  • InfluxDB / PostgreSQL
  • HL7 FHIR R4 / HAPI FHIR
  • LOINC / UCUM
  • Java / Spring Boot
  • Python
  • Flutter / React Native
  • Grafana
  • Kubernetes

Engagement models

Work with us the way that suits you

How we work

Dedicated product team

A stable, cross-functional team — engineers, design, QA, DevOps — that owns your roadmap quarter after quarter.

Fixed-scope delivery

A defined build with milestones, demos and a hard definition of done.

Embedded engineers

Senior engineers inside your team, in your tools and your stand-ups, with no hand-over boundary.

Working standards

What you can expect on every project

Engineering standards

Reviewed, version-controlled code

Every change goes through pull requests and peer review in your repository, with a clean history you own.

Automated testing in CI/CD

Unit, integration and API tests run in the pipeline on every change, so regressions are caught before release.

Security by default

Least-privilege access, secrets management, OWASP-aligned checks and environment separation from day one.

Production-ready by default

Idempotent APIs, audit trails, monitoring, alerting, backups and documented runbooks ship with every platform.

Frequently asked questions

Still unsure? Ask us directly — we reply within one business day.

Is our remote monitoring software a medical device?

It may be. Software that only stores and displays readings is often treated differently from software that interprets them or drives clinical decisions, but the answer depends on intended use and the market. Your regulatory lead decides classification under FDA rules, the EU MDR or local rules, and we build to the process that classification requires.

Are you ISO 13485 certified or able to get FDA clearance for us?

No. We do not hold ISO 13485 certification and we do not obtain clearances. The device manufacturer owns the quality system and regulatory submissions. We work inside your quality system and supply the software lifecycle, verification and cybersecurity documentation IEC 62304 and FDA or EU MDR submissions expect.

How do device readings get into the EHR?

We map each reading to a FHIR R4 Observation with a LOINC code and UCUM units, link it to the patient and device, and send it through the EHR's FHIR API or an HL7 v2 ORU feed where FHIR write is not available. See EHR development and integration.

What about cybersecurity requirements for connected devices?

In the US, section 524B of the FD&C Act requires cyber device submissions to include cybersecurity information such as a software bill of materials and a plan for post-market vulnerabilities. In Europe, IEC 81001-5-1 sets health software security activities. We build to these from the first sprint.

Can you work with devices we did not make?

Yes. Many programs use consumer or clinical devices from several manufacturers. We integrate through standard BLE health profiles, vendor SDKs or vendor clouds, and normalize the readings into one model.

Can the system run where connectivity is poor?

Yes. Apps and gateways store readings locally and sync when a connection returns, with timestamps from the device and duplicate detection on the server.

Tell us what you’re building. We’ll show you how we’d ship it.

Share a few lines about your project. A senior engineer — not a salesperson — replies within one business day.

Free AI audit Book a call